General-technologies TA500 SmarTach+COP : Multisystem Engine Analyser Instrukcja Użytkownika Strona 6

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 9
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 5
3.5 Additional functions
3.5.1 Minimum and Maximum functions (For COP and SPW modes)
TheTA500maintainsacontinuousrecordoftheminimumandmaximumreadingsofthe
functioncurrentlyselected.
1-TodisplaytheMinimumandMaximumreadings of themaindisplay, if notalready
selectedpress‘Secondary Function / Capture’ buttonmomentarily.
2-ToresettheMinimumandMaximumreadings,pressthePower On/Off / Reset’ button
momentarily.Thesevaluesarealsoresetwhenturningtheuniton.
Note:
•For the tachometer function (RPM) all Minimum and Maximum readings on the
secondarydisplaysareshownwiththelastdigitroundedto“0”.
3.5.2 Spark KVolt calibration function (For COP mode only)
The TA500 requires the user to calibrate the instrument in order to measure spark
KVolt in Coil on Plug and Coil near Plug ignition systems. This calibration uses the
measurement values obtained during the procedure to find the optimal measuring
parametersor a particulartype ofignition module, andcompensates for differences in
waveformandsignalstrength.
Once the TA500 has been calibrated on one of the ignition modules of the engine
beingdiagnosed,allthesubsequentmeasurementofsparkKVoltwillberelativetothe
calibrationvalue.
TocalibratetheTA500,followtheprocedureasdescribedin‘3.4.2MeasuringCoilon
PlugandCoilnearPlugignitionsystems’.
Page9
3.4.2 Spark plug wire ignition systems
1-Turntheinstrumenton.
2-Ifnotalreadyin
SPW(SparkPlugWire)mode,selectitbypressingtheIgnition System’
button.
3-Selectthenumberofcyclesfortheengineundermeasurementbypressingthe
Engine
Cyclesbuttonrepeatedlyuntilthedisplayshowsthecorrectsetting.
4-Select the measurement to show in the main display: RPM, spark burn time or
sparkKVolt.
5-Selectthemodeforthesecondarydisplay:MinimumandMaximumofthemaindisplay
orthecomplementarymeasurements.
6-Placethecapacitivepickupoveroneofthesparkplugwires,andproceedtoreadthe
measurementonthedisplay.
Sparkplugwire
Sparkplugwire
Capacitivepick-upat90°
Capacitivepick-upparallel
Fig.6-Capacitivepick-uponsparkplugwire
Page10
Important:
InordertoobtainconsistentresultswhenmeasuringSparkKVoltonsparkplugwires,
thepositionofthecapacitivepick-uprelativetothesparkplugwireshouldbethe
sameforeverymeasurement.
•An easy way to obtain consistent measurements, is to position the capacitive
pick-upeitherat90°orparalleltothesparkplugwire(Fig5),andthenrepeatthe
samepositioningforeverysparkplugwire
•SparkburntimeandRPMmeasurementsarenotsensitivetotheexactpositionof
thecapacitivepick-uprelativetothesparkplugwire,butithastobeplacedsothe
instrumentiscapableofdetectingthesignal.
•When several spark plug wires are routed or bunched close together, the
capacitive pick-up may receive signals from several wires at the same time,
which could cause erroneous measurements. In these situations it may be
necessarytoseparatethewireundermeasurementfromtheothers,inordertoreduce
interferenceandobtainanaccuratemeasurement.
Notes:
Immediatelyaftercalibration,theTA500willdisplayabaselinevalueof“10.0Spark
KVolt” by default.All the spark KVolt measurements obtained thereafter would be
relativestothe(value)moduleusedforcalibration.
•CalibrationdoesnothaveanyeffectonsparkburntimeorRPMmeasuredvalues
(theseareabsolute).
•IftheTA500is calibratedagain, theSpark KVoltvalues obtainedbefore andafter
calibrationmaynotbecomparable.
•If not calibrated, the TA500 may show a false 0.0 Spark KVolt’ reading when
measuringsparkKVoltonCoilonPlugandCoilnearPlugsystems.
Fig.7-Displayduringcalibration
Burn Time
Cycles
Peak
G7
G7
mS
Flashingletters
Przeglądanie stron 5
1 2 3 4 5 6 7 8 9

Komentarze do niniejszej Instrukcji